The blade posts are ground down occlusally, fig. 12, and smoothed off with a rubber wheel, fig. 13. The tissues are sutured closed, fig. 14, and the interocclusal clearance is carefully checked, fig. 15. After healing, fig. 16, the fixed bridge is cemented in permanently, fig. 17. A periapical film shows the intra-tooth blade, fig. 18.

Sometimes there is adequate bone height to insert a deep implant in between two teeth. The tissues are incised, reflected and the groove is made, figs. 19, 20, 21, 22, 23. The deeper implant, usually a double headed one, is inserted into the bone, figs. 24, 25, 26. The various instru-

182

1 Mandibular Blade post implants are smoothed off with a rubber wheel



Previous Page Page 182 Next Page
Copyright warning: This information is presented here for free for anyone to study online. We own exclusive internet copyrights on all content presented on this website. We use sophisticated technology to identify and legally close down websites that reproduce copyrighted content without permission - so please don’t do it.